According to Statista, in 2017 e-commerce sales worldwide amounted to $2.3 trillion. And this number is expected to grow in the coming years. This indicates that consumers and businesses have both moved their interactions online.
SOURCE: STATISTA.COM
Marketplaces are what make these interactions possible. In recent years, their number has increased. These newcomers are functioning alongside such giants as eBay, OpenTable, Uber, Airbnb, and Amazon. According to a research by Internet Retailer, 35 of the current top 75 online marketplaces launched between 2010 and 2015, including physical stores that went online. In this article, we outline how to start an online marketplace business and talk about their key benefits. But first let’s answer the question: What is a marketplace?
SOURCE: DIGITALCOMMERCE360.COM
In this article, we outline how to start an online marketplace business and talk about their key benefits. But first let’s answer the question: What is a marketplace website?
What is a marketplace?
An online marketplace, or an e-marketplace, is a website or app that serves as a mediator between customers and companies or individuals offering products or services in the B2B and B2C sectors. Marketplace owners usually don’t offer any products or services themselves. Their task is to provide a platform where marketplace participants interact.
There are four main types of e-marketplaces:
Vertical marketplaces offer products of the same type from different vendors.
Horizontal marketplaces offer different products that have similar characteristics.
Global marketplaces have no limitations and sell all kinds of products from different suppliers.
Hybrid marketplaces offer their own products as well as products from other companies while providing a platform for participants to complete transactions.
Internet Retailer analyzed the top 75 online marketplaces worldwide as of 2017 and came up with the following statistics:
SOURCE: DDIGITALCOMMERCE360.COM Top benefits of marketplace businesses
Considering marketplace growth and areas yet untapped by this technology, business owners can leverage the marketplace business model and build their own unique solutions. Below are some key benefits of running your own marketplace.
Efficiency
The cost of releasing a marketplace application is almost the same as the cost of launching an e-commerce website. Although the logic behind an e-marketplace is rather complex, its functionality can cater to the specific needs of many different vendors.
Understanding Reverse Osmosis Water Purification
Reverse Osmosis is a water purification technology that utilizes a semi-permeable membrane to remove ions, unwanted molecules, and larger particles from drinking water. By applying pressure to overcome the natural osmotic pressure, water is forced through the membrane, leaving contaminants behind. This process is similar to the natural osmotic mechanisms observed in plant roots and human kidneys, where water is selectively absorbed from surrounding environments.
The RO system is designed to purify water by removing various contaminants, including:
Salt
Sediment
Chlorine
Fluoride
Arsenic
Herbicides
Pesticides
The Working Principle of Reverse Osmosis
In a reverse osmosis system, water is pressurized and passed through a series of filters, including a sediment filter to trap particles, followed by a carbon filter that removes chlorine and other organic contaminants. The water then reaches the RO membrane, where dissolved solids, bacteria, and viruses are filtered out. The purified water is collected for use, while the waste containing the concentrated impurities is flushed away.
Key Advantages of Reverse Osmosis for Water Treatment
The benefits of using a reverse osmosis system for water treatment are numerous:
Purity: RO systems can remove up to 99% of dissolved salts (ions), particles, colloids, organics, bacteria, and pyrogens from the feed water (although an RO system should not be relied upon to remove 100% of bacteria and viruses).
Reduced Contaminants: Harmful dissolved contaminants are significantly reduced, making the water safer for consumption.
Lower Sodium Levels: RO systems are capable of reducing sodium from soft water.
Toxin Removal: Toxins such as lead, arsenic, and other heavy metals are effectively removed.
Improved Taste: Bad tastes and odors are reduced, resulting in better-tasting drinking water.
Culinary Benefits: Water purified by RO is better for cooking, as it does not alter the flavor of food.
Eco-Friendly: Using an RO system is more environmentally friendly than consuming bottled water, reducing plastic waste.
Ease of Installation and Maintenance: RO systems are generally easy to install under the kitchen sink and require minimal maintenance.
Cost-Effectiveness: While the initial investment may be higher, RO systems are cost-saving in the long run due to the reduced need for bottled water.
According to the Water Quality Association, RO systems can be particularly effective in areas where the local water supply contains significant amounts of TDS (Total Dissolved Solids) (Water Quality Association).
Environmental Impact and Sustainability
The environmental impact of bottled water is significant, with millions of plastic bottles ending up in landfills each year. In contrast, RO systems produce clean water on demand, reducing reliance on plastic bottles and contributing to environmental conservation. Moreover, modern RO systems are designed to be more water-efficient, addressing concerns about water wastage during the filtration process.
Conclusion
Reverse osmosis offers a comprehensive solution for water purification, combining health benefits, cost savings, and environmental sustainability. As water quality concerns continue to rise, RO systems provide a reliable and efficient way to ensure access to clean drinking water. With advancements in technology, these systems are becoming more accessible and user-friendly, making them an excellent investment for households and businesses alike.
The ARINC 429 Specification defines basic requirements for the transmission of digital data between commercial avionics systems.
For ease of design implementation and data communications, signal levels, timing, and protocol characteristics are specified.
ARINC 429 is designed to provide the interchangeability and interface of commercial aircraft Line Replaceable Units (LRUs).
As in a layman’s term, ARINC protocol is designed to support communication in the Local Area Network (LAN) of the avionics
ARINC 429 is also known as the Mark 33 Digital Information Transfer System (DITS) bus. Although used mostly in the field of avionics, these buses are also used in the field of ground vehicles, weapons systems, and other commercial and military equipment.
The word structure, the electrical component characteristics, and the protocol needed for the requirement of successful communication is defined in the specifications. The Simplex, twisted shielded pair data bus standard Mark 33 DITS bus is used by ARINC 429. Both the hardware and data formats needed for bus transmission are specified by ARINC 429.
A single connected transmitter or source consists of the hardware connected to from 1-20 receivers or sinks on one twisted wire pair. Data can only be transmitted in one direction (unidirectional connection), for bi-directional communication, it requires two channels or buses. FPGA
In a star or bus-drop topology, the modules, line replaceable units or LRUs, are most commonly configured. Multiple transmitters and receivers communicating on separate buses can be present in each LRU. Figure 1 shows the preferred connection topologies for the data bus. This simple architecture provides a highly efficient transfer of data, almost node-to-node connectivity.
A transmitter can only talk to a number of bus receivers, up to 20 on a single wire pair, with each receiver monitoring the related data continuously, but not accepting data reception. When large quantities of data have been transmitted, a transmitter can require acknowledgment from a receiv
As compared to a hard-wired handshake, this handshaking is done using a specific word style. Two twisted pairs comprising two channels are sufficient to carry information back and forth, one for each direction when this two-way communication format is needed.
The transmission of the LRU source consists of 32-bit words containing a portion of 24-bit data containing the actual data and an 8-bit label describing the data itself. LRUs do not have an address assigned by ARINC 429, but rather an equipment ID numbers that allow device management and file transfer of equipment to be grouped into systems
A null or zero voltage of at least 4 bits distinguishes sequential words. By using this null interval between words, a separate clock signal is unnecessary. That’s why this signal is known as a self-clocking signal. Transmission rates can be either at a low speed of 12.5 kHz or a high speed of 100 kHz.
For the transfer bus media, a 78 x shielded twisted pair cable is used. The shield needs to be grounded at either end and all junctions along the bus. The transmitting source output impedance should be 75Ω ± 5Ω equally split between Line A and Line B.
This balanced output should closely match the cable impedance. There must be a minimum effective input impedance of 8k x for the receiving sink. There is no definition of the maximum length, as it depends on the number of sink receivers, the drain of the sink, and the source power
Most systems are designed for less than 150 feet, but if conditions permit, they can be extended up to 300 feet and beyond. Fig 2 shows the cable attributes for the ARINC 429.
ARINC 429 assigns the first 8 bits as the wordmark, bits 9 and 10 are the Source-Destination Indicator (SDI), bits 11 through to 28 provide data information, bits 29 through to 31 are the Sign-Status Matrix (SSM), and bit 32 is a Parity Bit.
ARINC 429 data words are 32-bit words made up of five primary fields:• Parity – 1-bit
ARINC uses odd parity as an error check to ensure precise data reception. The number of transmitted Logic 1s in each word is an odd number, with bit 32 set or cleared to get the odd count. ARINC 429 specifies no method of error correction, only error detection.
Depending on the word Label, which indicates the form of data is being transmitted, the SSM field may provide different information. This field can be used to view the word information’s sign or location or to report the operating status of the source system and is dependent on the data type.
Bit 31 Bit 30 Status (BCD)
0 0 Plus, North, East, Right, To, Above
0 1 No Computed Data (NCD)
1 0 Functional Test (FT)
1 1 Minus, South, West, Left, From, Below
Table 1. SSM for BCD format
Bit 31 Bit 30 Status (BNR)
0 0 Failure Warning
0 1 No Computed Data (NCD)
1 0 Functional Test (FT)
1 1 Normal Operation
Table 2. SSM for BNR format
• Data – 19-bits
ARINC 429 identifies bits 11-29 as those which contain the data information for the word. The data pieces, indeed the entire word of ARINC 429, can be formatted very flexibly. When the data words are transmitted on the ARINC bus, the mark is transmitted first, MSB first, followed by the remainder of the bit field, LSB first.
• Source/Destination Identifier (SDI) – 2-bits
Bits 9-10 are used by the Source/Destination Identifier-SDI-and are optional under the ARINC 429 specification. To determine the receiver, the data is intended for the SDI may be used to identify the source that transmits the data or by several receivers. Instead of using them as an SDI sector, bits 9-10 can be used for higher resolution data.
The SDI is interpreted as an extension to the term Label when used as an identifier.
• Label – 8-bits
The mark is used to define the word’s data type (BNR, BCD, Discrete, etc.) and may contain instructional or data reporting information. Labels can be further refined by using the first 3-bits of the data field, Bits 11-13, as an Equipment Identifier to identify the bus transmission source. Equipment IDs are expressed in hexadecimal form as values.
In an ARINC transmission, the label is always sent first and is a necessary sector, as is the parity bit. Labels are first transmitted by MSB, followed by the remainder of the ARINC phrase, first transmitted by LSB
Data Types specified in ARINC 429:
Binary Coded Decimal (BCD):
The advantage of the Binary Coded Decimal technique is that each decimal digit is represented in the same way as Hexadecimal by a group of 4 binary digits/bits. So, for 10 decimal digits, we need a four-bit binary code (0-to-9). For displaying every decimal digit, the BCD format uses four bits of the data field.
To provide 5 binary values, up to 5 sub-fields can be used, with only 3 data field bits in the most significant sub-field. Bits 27-29 are padded with zeros if the Most Significant Digit is greater than 7 and the second sub-field becomes the Most Significant Digit, enabling the representation of 4 binary values instead of 5. The SSM field represents the sign of the data.
Binary Number Representation (BNR):
The fractional complement of the binary two. BNR coding stores information as a binary number. The sign of the data is stated with the bit 29, and a 1 indicates a negative number. MSB of the data is given by the bit 28.
Discrete Data:
It can be a combination of BNR, BCD, or ISO #5 bits. By setting or clearing predefined bits in the word data field, Pass/Fail, Activated/Non-Activated, and True/False conditions relating to device or subsystem operational activity can be described
Maintenance Data / Acknowledge:
Maintenance details and acknowledgment means duplex or two-way communication between source and sink. For the LRU to send and receive data, two ARINC channels are required, because ARINC 429 provides for single-way simplex transmission only. Maintenance messages typically involve the exchange of a series of messages and mostly use a bit-oriented protocol, such as the Williamsburg/Buckhorn protocol.
Williamsburg/Buckhorn Protoco
A bit-oriented protocol used to transfer files on the ARINC Data bus. If we require to transmit data more than 21 bits, file transfer protocol becomes a necessary and important factor. Source and sink units need to first create a handshake when initializing a file transfer with the bit-oriented protocol to decide a standard protocol that can be used by both the transmitter and the receiver.
A Word Send Request (RTS) containing a destination code and word count is transmitted. To ensure accuracy, the receiver responds with a Clear to Send word (CTS), re-transmitting back the destination and word count information. Upon verified receipt of the CTS files, the file transfer begins with the source.
Applications of ARINC 429 standard and Extending to other ARINC standards:
High reliability and small data rates at the cost of wire weight are provided by the unidirectional ARINC 429 network. In the early 1980s, the ARINC 429 was first used on the Airbus A-310 and the Boeing B-757 and B-767 aircraft.
In the 21st century, modern airplane designs continue to use the ARINC 429 bus for data transmission. The relative simplicity and integrity of the bus, as well as the ease of certification, are features that contribute to the continued selection of ARINC 429 buses when the required data bandwidth is not critical.
Military aircraft typically use a high-speed, bi-directional protocol specified in the Military Specifications of MIL-STD-1553. The interface DNx-429-516 ARINC-429 of United Electronic Industries (UEI) is intended for use with the company’s UEI Cube and RACKtangle chassis
It is compatible with the commercial aviation ARINC-429 data format. Few other manufacturers have developed ARINC 429 based devices such as the North Atlantic Industries offers the AR429/575 module and a broad range of ARINC-429 Interface boards is provided by Alta Data Technologies.
One particular item is the PMC-A429HD, which provides RX and TX ARINC-429 channels with 16, 32, or 48 channels. Interface cards such as USB 429, OmniBusBox II, OmniBus II PCIe, AB3000, and MX5 series for a range of computer platforms, box products as controllers or connected via USB or Ethernet, and related software tools are included in the Ballard ARINC 429 products from Astronics Corporation. A newer system is installed on the 777 listed as ARINC 629 by Boeing, and some aircraft are using alternative systems to try and reduce the necessary wire weight and exchange data at a higher rate than is possible with ARINC 429.